Toilet Clear Floor Space

The accessible urinal is required to have a 30 x 48 760 mm x 1220 mm clear floor or ground space positioned for forward approach.
Toilet clear floor space. Position at most elements clear floor or ground space can be positioned for either a forward or a side approach. Where urinals are placed in a alcove deeper than 24 610 mm then the alcove must be 36 min 915 mm wide. Plan a clear floor space of at least 30 inches from the front edge of all fixtures lavatory toilet bidet tub and shower to any opposite bath fixture wall or obstacle. Refer to figure a.
Doors can swing into the turning space. The door swing is allowed to overlap the clearance for a lavatory in a toilet room as long as there is a 30 760 mm x 48 1220 mm clear floor space beyond the arc of the door. For better usability a forward approach is required at certain elements including dining and work surfaces drinking fountains lavatories and most sinks. They cannot swing into the clearance required at plumbing fixtures except in single user toilet rooms where clear floor space 30 minimum by 48 minimum is provided in the room beyond the arc of the door swing 603 2 3 ex.
Refer to figure b. To pass state building code every fixture in the bathroom including the toilet must have a minimum of 21 inches of clear floor space in front of it. 603 2 3 door swing exception 2.